Siemens Advia Centaur XP analysis system with acridinium ester immunoassay technologySiemens
Advia Centaur XP
Siemens Advia Centaur XP analysis system with acridinium ester immunoassay technology
Siemens
Advia Centaur XP
VB acresce IVA
€ 6.722
Condição
Usado
Localização
Borken 

Dados básicos
- Designação da máquina:
- Siemens Advia Centaur XP analysis system with acridinium ester immunoassay technology
- Fabricante:
- Siemens
- Modelo:
- Advia Centaur XP
- Condição:
- usado
Preço e localização
VB acresce IVA
€ 6.722
- Localização:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Ligar
Detalhes da oferta
- ID do anúncio:
- A6779482
- Número de referência:
- 24568
- Atualização:
- por último em 21.10.2026
Descrição
Siemens Advia Centaur XP Analysis System – Acridinium Ester Immunoassay Technology
Siemens Healthineers service and maintenance up to
Modern AE immunoassay technology
Meeting clinical requirements through acridinium ester (AE) technology, which ensures the necessary flexibility and sensitivity for new and innovative assays.
Comprehensive diagnostic evaluation of various disease patterns thanks to a test menu with over 70 different assays.
Simplified inventory management and lower costs through the use of the same ready-to-use reagents on all ADVIA Centaur analysis systems.
Simplified operation, continuous operation
All samples, reagents, and consumables can be loaded and unloaded during continuous operation.
Easier training and operation thanks to an intuitive, icon-based user interface.
Fewer operator interventions, as the daily maintenance effort is low and the system does not need to be cleaned monthly or started up daily.
New and updated test definitions can be read in by the customer by simply scanning the 2D barcodes contained in the package insert.
Consistent, predictable turnaround time (TAT) and accuracy
Up to 240 tests/hour for a short turnaround time, even during peak times.
Rapid prioritization of emergency samples is possible at any time thanks to a dedicated access point (STAT port).
Disposable pipette tips prevent carryover and contamination of samples.
Automatic performance of repeat and confirmation tests for reactive hepatitis B surface antigen samples using Siemens Healthineers' SMART algorithms.
Direct connection option
Adaptation to different sample volumes through easy connection to Aptio and VersaCell® X3 automation solutions.
Efficient operation thanks to diagnostic IT including the CentraLink® data management system
Atellica Process Manager and Smart Remote Services for Diagnostics
Direct pipetting from the automation solution using point-in-space technology.
Shorter processing times for emergency samples thanks to a dedicated STAT port that allows loading with emergency samples from the front even when connected to an automation solution.
Technical specifications
Bedpfx Aohr Rw Iolbjww
Product specifications
System type: Random-access immunoassay system
Throughput: Up to 240 tests per hour
Time to first test result
18 minutes, further results at 15-second intervals (method-dependent)
Methods capacity on board: 30 test methods
Indication groups
Allergy, anemia, diabetes, fertility, hepatitis, HIV, immunosuppressants, infectious serology, cardiology,
bone metabolism, liver fibrosis, adrenal function, oncology, thyroid disorders, sepsis, therapeutic drug monitoring (TDM)
Continuous operation
Loading and unloading of samples and consumables at any time during continuous operation. This includes sample racks, emergency samples, reagents, additional reagents, reaction cuvettes, sample tips, calibrators, controls, washing solutions, water and waste.
Samples and sample management: Sample tubes
3 ml, 5 ml, 7 ml and 10 ml tubes, 1 ml and 2 ml secondary vessels, microvessels
Sample input
Universal rack with 5 positions for different tube types, total capacity 180 samples; loading and unloading during continuous operation
Validated sample types
Serum, plasma, urine, whole blood (depending on the test method)
Sample volume per test
O anúncio foi traduzido automaticamente. Podem ocorrer erros de tradução.
Siemens Healthineers service and maintenance up to
Modern AE immunoassay technology
Meeting clinical requirements through acridinium ester (AE) technology, which ensures the necessary flexibility and sensitivity for new and innovative assays.
Comprehensive diagnostic evaluation of various disease patterns thanks to a test menu with over 70 different assays.
Simplified inventory management and lower costs through the use of the same ready-to-use reagents on all ADVIA Centaur analysis systems.
Simplified operation, continuous operation
All samples, reagents, and consumables can be loaded and unloaded during continuous operation.
Easier training and operation thanks to an intuitive, icon-based user interface.
Fewer operator interventions, as the daily maintenance effort is low and the system does not need to be cleaned monthly or started up daily.
New and updated test definitions can be read in by the customer by simply scanning the 2D barcodes contained in the package insert.
Consistent, predictable turnaround time (TAT) and accuracy
Up to 240 tests/hour for a short turnaround time, even during peak times.
Rapid prioritization of emergency samples is possible at any time thanks to a dedicated access point (STAT port).
Disposable pipette tips prevent carryover and contamination of samples.
Automatic performance of repeat and confirmation tests for reactive hepatitis B surface antigen samples using Siemens Healthineers' SMART algorithms.
Direct connection option
Adaptation to different sample volumes through easy connection to Aptio and VersaCell® X3 automation solutions.
Efficient operation thanks to diagnostic IT including the CentraLink® data management system
Atellica Process Manager and Smart Remote Services for Diagnostics
Direct pipetting from the automation solution using point-in-space technology.
Shorter processing times for emergency samples thanks to a dedicated STAT port that allows loading with emergency samples from the front even when connected to an automation solution.
Technical specifications
Bedpfx Aohr Rw Iolbjww
Product specifications
System type: Random-access immunoassay system
Throughput: Up to 240 tests per hour
Time to first test result
18 minutes, further results at 15-second intervals (method-dependent)
Methods capacity on board: 30 test methods
Indication groups
Allergy, anemia, diabetes, fertility, hepatitis, HIV, immunosuppressants, infectious serology, cardiology,
bone metabolism, liver fibrosis, adrenal function, oncology, thyroid disorders, sepsis, therapeutic drug monitoring (TDM)
Continuous operation
Loading and unloading of samples and consumables at any time during continuous operation. This includes sample racks, emergency samples, reagents, additional reagents, reaction cuvettes, sample tips, calibrators, controls, washing solutions, water and waste.
Samples and sample management: Sample tubes
3 ml, 5 ml, 7 ml and 10 ml tubes, 1 ml and 2 ml secondary vessels, microvessels
Sample input
Universal rack with 5 positions for different tube types, total capacity 180 samples; loading and unloading during continuous operation
Validated sample types
Serum, plasma, urine, whole blood (depending on the test method)
Sample volume per test
O anúncio foi traduzido automaticamente. Podem ocorrer erros de tradução.
Fornecedor
Nota: Registe-se gratuitamente ou faça login, para aceder a todas as informações.
Registrado desde: 2008
532 Anúncios online
Enviar pedido
Telefone & Fax
+49 2862 ... anúncios
Estes anúncios também podem ser do seu interesse.
Com êxito
A sua mensagem foi enviada.
Anúncio classificado
Borken
9.271 km
DIASORIN Liaison Analisador de Imunodiagnóstico por Imunoensaio Tipo 2229
DiaSorinLIAISON
DiaSorinLIAISON
Com êxito
A sua mensagem foi enviada.
Anúncio classificado
Белослав
10.281 km
Analisador imunológico Siemens ADVIA
SIEMENS ADVIACentaur CP
SIEMENS ADVIACentaur CP
Com êxito
A sua mensagem foi enviada.
Anúncio classificado
Győr
9.726 km
Analisador de química clínica
Instrumentation LaboratoryILab Aries
Instrumentation LaboratoryILab Aries
O seu anúncio foi eliminado com sucesso
Ocorreu um erro