Hitech Instruments GIR250 Gas Analyser
Hitech Instruments GIR250

Condição
Usado
Localização
Duxford Reino Unido
Hitech Instruments GIR250 Gas Analyser Hitech Instruments GIR250
Hitech Instruments GIR250 Gas Analyser Hitech Instruments GIR250
Hitech Instruments GIR250 Gas Analyser Hitech Instruments GIR250
Hitech Instruments GIR250 Gas Analyser Hitech Instruments GIR250
Hitech Instruments GIR250 Gas Analyser Hitech Instruments GIR250
Hitech Instruments GIR250 Gas Analyser Hitech Instruments GIR250
more Images
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250
Hitech Instruments GIR250

Dados básicos

Designação da máquina:
Hitech Instruments GIR250 Gas Analyser
Fabricante:
Hitech Instruments
Modelo:
GIR250
Condição:
usado

Preço e localização

Localização:
Duxford, UK Reino Unido
Ligar

Detalhes da oferta

ID do anúncio:
A20123055
Número de referência:
240850/7B
Atualização:
por último em 02.10.2025

Descrição

This listing is for the Hitech Instruments GIR250 Gas Analyser

The unit is in full working condition and is ready for immediate use

The GIR250 is a bench‑top / transportable analyser designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously in gas samples.

It is made by Hitech Instruments (now part of the MTL / Eaton group).

Its design emphasizes ease of use, reliability, and low maintenance cost.

Other supporting features:

The instrument can be programmed with pass/fail criteria for each gas (alarms).

It provides analog outputs, typically 4–20 mA, for external logging or control systems.

Calibration is designed to be simple (via the front panel keypad) to reduce training burden.

The O₂ galvanic cell is user-replaceable (i.e. maintenance can be performed in the field).

Mechanical, Electrical & Operational Details
Dcsdpoxhdqtofx Abwsp

The GIR250 is housed in a rugged, transportable case (lab-style) so it can be used as a benchtop or mobile analyser.

Sample inlet and outlet connections use 0.25″ (~6 mm) tubing.

The sample system should avoid condensation and contaminants; non‑condensing sample environment is required.

Operating ambient temperature: –5 to +40 °C (for non‑condensing conditions)

Power / interface: standard for bench‑top analysers (the catalogue doesn’t always detail it, but likely mains or DC supply, suitable for lab use)

Typical Applications & Suitability

Because it can measure both O₂ and CO₂ in a single unit, the GIR250 is used in applications such as:

Respiration / breathing gas analysis / Douglas bag analysis (i.e. in physiological or experimental gas mixture measurement)

Fermentation / bioprocess monitoring (where O₂ and CO₂ both matter)

Gas mixture / inertisation / process gas quality (checking gas purity, calibrating mixtures)

It is not primarily intended for measuring very low trace levels (ppm-level) of O₂ or CO₂ unless its ranges are suitably adapted or specified. The design is more for percent-range analysis

Fornecedor

Registrado desde: 2019

772 Anúncios online

Ligar

Enviar pedido

Terrenous 
Alemanha
Áustria
Suíça
Estados Unidos da América
Reino Unido
França
Bélgica
Espanha
México
Itália
Países Baixos
Polónia
Federação Russa
Bielorrússia (República da Bielorrússia)
Ucrânia
Estónia
Turquia
Nova Zelândia
Irlanda
República Checa
Dinamarca
Finlândia
Suécia
Noruega
Luxemburgo
Grécia
Lituânia
Letónia
Islândia
Portugal
Brasil
Venezuela
Argentina
Hungria
Eslováquia
Roménia
Moldávia
Eslovénia
Sérvia
Montenegro
Albânia
Croácia
Bulgária
Macedónia do Norte
Bósnia e Herzegovina
Israel
Egito
Marrocos
Índia
Indonésia
Coreia do Sul
Japão
Tailândia
Malásia
Vietname
China, República Popular
Taiwan
Irão
Bangladeche
Nota: O seu pedido será encaminhado a todos os vendedores da categoria de máquinas. Desta forma, pode receber um grande número de propostas.
Não foi possível enviar o pedido. Por favor, tente novamente mais tarde.

Telefone & Fax

+44 20 38... anúncios